OMD-2008
General Details
5 ppm + 15 ppm Bilge Alarm according to IMO Resolution MEPC.107 (49)
Technical Details
Property | Value |
---|---|
Range (measurement & indication) | 0 – 30 ppm, Trend up to 50ppm |
Range (IMO specification) | 0 – 15 ppm (according IMO regulations) |
Accuracy | better than IMO MEPC.107(49) |
Electrical power supply | 24V – 240V, AC or DC, Automatic Voltage Selection |
Electrical power consumption | < 10 VA |
Sample | Oily water from separator outlet, 0,1 – 4 l/min |
Sample temperature range | +1°C to +65°C |
Sample connections | R 1/4″ Female |
Alarm 1 & 2 Set Points | 1 – 15ppm (independently adjustable) |
Alarm 1 operating delay for annunciation | 1 – 540 sec |
Alarm 2 operating delay for control | 1 – 10 sec |
Alarm contacts | 2 independently adjustable switchover contacts |
Alarm contact operation mode | De-energized in Alarm State |
Alarm contact ratings | 3A, 240V each |
Alarm output | 0 – 20 mA or 4 – 20 mA, for 0-30ppm reversible, ext. Load<150Ω |
Display | Graphic Display |
Ambient temperature | +1°C to +55°C |
Class of protection | IP 65 |
Dimension | 360 x 240 x 100 mm (WxHxD) |
Weight | 5,4 kgs |
Ask about this product
Contact form