Ship of a Polish owner
Restoration of a burnt-out DECCA ISIS control panel
Following a fire in the ship's engine control room, the DECCA ISIS alarm panel was almost completely burnt out. We took on its repair — even though at first replacing the panel with a new one seemed the only option
Scope of works
- Detailed examination of every circuit in the panel
- Repair of modules that could be restored
- Rebuilding from scratch the components that were destroyed beyond repair
- Restoring control of alarm sirens, lights and state loggers
- Testing communication with engine room equipment
The DECCA system comprises control circuits for numerous modules — alarm sirens, light signalling and alarm state loggers — communicating directly with every piece of equipment operating in the ship's engine room
Through analysis of the electrical circuits we managed to recover every damaged module. Components that were completely burnt out were rebuilt from scratch, based on the ship's documentation and using working modules as a reference
The repair cost turned out to be many times lower than buying a new panel, and the turnaround time far shorter than waiting for a unit ordered from the manufacturer
Gallery
Similar scope of works at your site?
We will prepare a quote and schedule tailored to your facility or vessel